By Brands

TES-3063/3064 Power AC/DC Clamp Meter

Category: Power Clamp Meter
True Power & Apparent power measurement
Input
Resolution
Accuracy
Frequency range
Overload protection
V<130V, A<150A
0.01
+/- (2%+5)
45Hz - 500Hz
600V/1100A
V>130V, A<150A
V<130V, A>150A
V>130V, A>150A
0.1
+/- (2%+1)
DCA
Range
Resolution
Accuracy
Overload protection
1000A
0.1A
+/- (1.5%rdg + 5dgts)
1100A
ACA
Range
Resolution
Accuracy
Frequency range
Overload protection
1000A
0.1A
+/- (1.5%rdg + 5dgts)
45Hz - 500Hz
1100A
‧Crest Factor: <4 for stated accuracy
DCV
Range
Resolution
Accuracy
Input Impedance
Overload protection
600V
0.1V
+/- (0.5%rdg + 5dgts)
1M Ω
600V
ACV
Range
Resolution
Accuracy
Input Impedance
Frequency range
Overload rotection
600V
0.1V
+/- (0.5%rdg + 5dgts)
1M Ω
45Hz - 500Hz
600Vms
‧Crest Factor: <3 for stated accuracy
Peak Indication
Range
Resolution
Accuracy
Overload protection
20A - 80A
0.1A
+/- (10%rdg + 10dgts)
1100A
80A - 1000A
+/- (6%rdg + 10dgts)
‧Peak Detect Acquisitions Time<=1ms
Peak Indication
Range
Resolution
Accuracy
Overload protection
20V - 80V
0.1V
+/- (10%rdg + 10dgts)
600Vrms
80V - 600V
+/- (6%rdg + 10dgts)
‧Peak Detect Acquisitions Time<=1ms
Audible continuity
Range
Continuity beeper
Open circuit voltage
Overload protection
<=0.050
<=3.2V
600Vrms
Resistance ( Ω )
Range
Resolution
Accuracy
Frequency range
Overload protection
10K Ω
1 Ω
+/- (1%rdg + 5dgts)
<=3.2V
600Vrms
Diode test
Range
Resolution
Overload protection
0.001V
600Vrms
Frequency (Hz)
Range
Resolution
Accuracy
Voltage sensitivity
Overload protection
1KHz
0.1Hz
+/- (0.5%rdg + 5dgts)
10V or 10A
600V / 1100A
5KHz
1Hz
Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software
GENERAL SPECIFICATIONS
Maximum Voltage between any
terminal and earth ground
600Vrms
Numerical Dual Display 4 digit liquid crystal display (LCD) maximum reding 9999.
Bargraph display 40 Segments.
Battery Life 30hr approx. (Alkaline)
Jaw Opening Diameter Cables f 46mm.
Operating Temperature and Humidity 0 ℃to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing.
Storage Temperature and Humidity -10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing.
Dimensions 260mm(L) x 93mm(W) x 45mm(H)
Weight Approx. 450g
Accessories Carrying Case, Test leads, One 9V Battery & Instruction manual